Replication Fails With "The Replication Source and Target Have Incompatible Configurations" (KBA5381)
KBA
KBA# 5381
Issue
An initial or incremental replication job may fail with the message "The replication source and target have incompatible configurations." The only further direction provided is to contact Delphix Support.
Applicable Delphix Versions
- Click here to view the versions of the Delphix engine to which this article applies
-
Major Release
All Sub Releases
6.0 6.0.0.0, 6.0.1.0, 6.0.1.1, 6.0.2.0, 6.0.2.1, 6.0.3.0, 6.0.3.1, 6.0.4.0, 6.0.4.1 5.3 5.3.0.0, 5.3.0.1, 5.3.0.2, 5.3.0.3, 5.3.1.0, 5.3.1.1, 5.3.1.2, 5.3.2.0, 5.3.3.0, 5.3.3.1, 5.3.4.0, 5.3.5.0 5.3.6.0, 5.3.7.0, 5.3.7.1, 5.3.8.0, 5.3.8.1, 5.3.9.0 5.2 5.2.5.0, 5.2.5.1, 5.2.6.0, 5.2.6.1
Resolution
The message indicates network security properties are mismatched between the Source and Target Replication Engines. A user with sysadmin privileges can log into the System Setup UI and review the Custom Authorizations settings to determine if client or server authorization is configured on one Engine and not the other, by comparing the values in the Network Security pane. Example:
In the instance where a mismatch occurs between Engines, one will have Perform (client or server) authorization for Replication enabled where the other Engine does not.
Related Articles
The following articles may provide more information or related information to this article: