TB107 Management Service and/or VDBs Unavailable After Storage Expansion Attempted
Alert Type
Availability
Impact
During an attempt to expand storage on one or more existing devices, the Continuous Data (formerly Virtualization) Engine becomes unresponsive, the management interface becomes unavailable, and VDBs may also become unresponsive or crash. Device expansion does not complete. Rebooting does not restore operation.
Contributing Factors
This article applies to the following versions of the Delphix engine:
Date | Release |
---|---|
Apr 13, 2023 | 10.0.0.0 |
Mar 13, 2023 | Mar 20, 2023 | 9.0.0.0 | 9.0.0.1 |
Feb 13, 2023 | 8.0.0.0 |
Jan 12, 2023 | 7.0.0.0 |
Releases Prior to 2023 | |
Major Release | All Sub Releases |
6.0 | 6.0.17.0, 6.0.17.1, 6.0.17.2 |
Symptoms
The engine management interface becomes unavailable and VDBs may become unresponsive after an attempt to expand a storage device, rendering the engine unresponsive. Device expansion does not complete. Since the IO pipeline is stalled, targets could see “NFS server not responding” type errors in the syslog/console of affected target environments. Rebooting the engine does not restore operation.
Relief/Workaround
Upgrade to Continuous Data 11.0.0.0 or later.
Resolution
This issue is fully resolved in Continuous Data 11.0.0.0 and later versions. A reboot upgrade is required for the fix to be effective in upgrade to 11.0.0.0; upgrades to 12.0.0.0 or later do not require a reboot upgrade, and fix can be delivered in a deferred upgrade (Delay the reboot).
Additional Information
N/A