Skip to main content
Delphix

Connections to Sybase DB do not request larger network packet sizes

 

 

Applicable Delphix Versions

 

Major Release

All Sub Releases

5.2 5.2.2.0, 5.2.2.1, 5.2.3.0

5.1

5.1.0.0, 5.1.1.0, 5.1.2.0, 5.1.3.0, 5.1.4.0, 5.1.5.0, 5.1.5.1, 5.1.6.0, 5.1.7.0, 5.1.8.0, 5.1.8.1, 5.1.9.0

5.0

5.0.1.0, 5.0.1.1, 5.0.2.0, 5.0.2.1, 5.0.2.2, 5.0.2.3, 5.0.3.0, 5.0.3.1, 5.0.4.0, 5.0.4.1 ,5.0.5.0, 5.0.5.1, 5.0.5.2, 5.0.5.3, 5.0.5.4

4.3

4.3.1.0, 4.3.2.0, 4.3.2.1, 4.3.3.0, 4.3.4.0, 4.3.4.1, 4.3.5.0

4.2

4.2.0.0, 4.2.0.3, 4.2.1.0, 4.2.1.1, 4.2.2.0, 4.2.2.1, 4.2.3.0, 4.2.4.0 , 4.2.5.0, 4.2.5.1

Issue

Connections to Sybase DB do not request larger network packet sizes.

Troubleshooting

The network packet size used by jConnect to communicate with Adaptive Server is now based on the default network packet size provided by the Adaptive Server. This is negotiated as part of the login process. In previous versions, the drivers would default to 512 bytes as the packet size.

Resolution

Increase the default network packet size on the Sybase server.